F-LINK SOFTWARE UPDATE: New version 3.0.4
Content

Grade 3, new hardware and a range of fixes
Version 3.0.4 expands support with the JA-108K control panel, a full set of settings for the EN 50131-1 grade 3 standard, new peripherals, and fixes a number of bugs that could affect configuration accuracy or the behaviour of the graphical interface.
What's new?
JA-108K support
The JA-108K control panel is now fully integrated into F-Link — including the EN 50131-1 Grade 3 system profile and all accompanying peripheral and system parameter settings.
EN 50131-1 Grade 3 support
The new version introduces a complete system profile for Grade 3 on the JA-108K. It includes:
- Configuration of peripherals JA-116E, JA-111H TRB, JA-113A and JA-113M to meet the requirements of the standard
- Monitoring of the minimum required peripheral firmware version
- Restriction of PCO settings and system parameters of the control panel to comply with the profile
- New system events:
- High voltage or current draw on the bus
- Recording of configuration write failures
- Recording of "Unknown user" in case of invalid authorisation
- Insurmountable obstruction when exiting service mode if an antimasking fault is active on a detector connected via JA-111H TRB
- New behaviour when the maximum number of invalid code login attempts is exceeded
- Low residual energy indication in JA-113A diagnostics
- Prohibition of use of identification cards and tags for users
- New settings section "Advanced settings" in the Parameters tab
New peripherals: JB-112TH and JB-112TP
F-Link 3.0.4 now supports CO₂-measuring thermostats — JB-112TH and JB-112TP.
Minor configuration improvements
- JA-151R: new parameter "Connection without battery"
- Additional information added in the authorisation element learning dialog when learning MIFARE-standard elements by presenting a tag
- JA-156J: parameters "Optical signalling" and "Acoustic signalling" have been merged into one — "Optical and acoustic signalling"; a "Button press signalling" parameter has also been added
What's fixed?
Factory values and default settings
- JA-112J: incorrect factory value of the "PG control" parameter corrected to "PG on/PG off"
- JB-128N: factory values for PG outputs and pump protection and anti-freeze protection parameters corrected
- JB-111TH, JB-111TP, JB-151TH, JB-151TP: incorrect default thermostat values and display in non-Czech language versions corrected
- JA-112M: settings updated in the EN 50131-1 Grade 2 and Incert profile
- JA-111H AD TRB: parameters "TMP input" and "LED indication" corrected
False incompatibility reports
- JA-110R-80 and JA-111R-80 incorrectly reported incompatibility
- JA-121PB incorrectly reported incompatibility in JA-101K and JA-106K control panels
- Invalid "Settings do not meet the selected profile" message when exiting service mode on systems with the default profile
User interface fixes
- JA-156J, JA-157J, JA-154J MS II, JA-152J MS II: schematic icons and object map icons corrected
- JA-162M: alignment of DIP switch display in the internal settings preview
- Segment keypads: corrected swapping of A/B lock display on mouse hover
- Firmware update dialog: persistent "Always on top" priority removed — other windows can now correctly be brought to the foreground
- Update loop on a new factory-fresh control panel — fixed
- Incorrect event ordering in the Events from memory dialog — fixed
- Incorrect LED indication settings for JA-111R, JA-112R, JA-151R — fixed