Jablotron
  • Wishlist

Control of the electric water shut-off valve by PEVEKO version J0J1

Content

The JABLOTRON 100+ security system enables the PG and electric valve to shut off the water supply with open-close logic, thus increasing the security of the building. The advantage of this type of valve is also an emergency condition for permanent closing with the need for manual unblocking.

The valve can be controlled by the user

Locally by keypad segmentRemotely using the MyJABLOTRON appSMS commandLocally with the button

Required equipment

Software

SKPB PEVEKO
water valve

SKPB 4015.2AKV/J0J1
SKPB 4020.2AKV/J0J1
SKPB 4025.2AKV/J0J1

Wiring

Wiring requires knowledge of the manuals of all components used. 

The figure below shows a schematic of an example of connecting the valve drive unit to the JA-114HN module.

  • The circuit uses a 4 input and 4 output PG bus module to control and monitor the status of the valve.
  • The valve responds to a pulse shorter than 2 s (opening/closing), in case of a longer pulse than 3 s it is an emergency condition which is permanent until the control button is pressed directly on the valve.
  • Valve wiring description: red wire - 12 V, black wire - GND, green wire - valve status, white wire - control.

Connecting the water shut-off to the PG output module

Setup and programming

  1. In F-Link, on the PG Outputs page, set the behavior of the three PG outputs. The first will generate a 1s pulse for standard valve control. The second one with a 3s pulse for an emergency condition reacting to a flood in the building. We will use the third PG to monitor the valve status using the JA-114HN input and then display it on the keypad segment.

PG output programming

  1. For the JA-114HN 4-input and 4-output bus module, set the corresponding PG and input 1 behavior.
  1. To set up the control and indicator segments on the keyboard, you need to open the internal settings on the Devices tab using the Enter button. For the respective segment, select the PG output and assign it the control function "PG indicates/controls". In this case, we indicate PG3 (Water Status) and control PG1 (Water ON/OFF).

Setting the keypad segment

Set the segment for controlling the PG1 output with on and off and authorization selection. When authorization is required, authorized users will need to set permissions to control PG1 in the Users tab.

Local and remote control

The water shut-off can be controlled both locally from the keypad segment and remotely outside the building. For the remote method, the MyJABLOTRON web or mobile app can be used by clicking on the virtual segment or SMS command with a configurable text.

Control via SMS commands

Mobile app MyJABLOTRON
Web app MyJABLOTRON